In this study, we developed and validated a sensitive analytical method to quantify baphicacanthin A in mouse plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The standard calibration curves for baphicacanthin A ranged from 0.5 to 200 ng/mL and were linear, with an r2 of 0.985. The inter- and intra-day accuracy and precision and the stability fell within the acceptance criteria. Besides, we investigated the pharmacokinetics of baphicacanthin A following its intravenous (5 mg/kg) and oral administration (30 mg/kg).
Intravenously injected baphicacanthin A showed biphasic elimination kinetics with high clearance and volume of distribution values. Furthermore, baphicacanthin A showed a rapid absorption but low aqueous solubility (182.51±0.20 mg/mL), resulting in low plasma concentrations and low oral bioavailability (2.49%). Thus, we successfully documented the pharmacokinetic properties of baphicacanthin A using this newly developed sensitive LC-MS/MS quantification method, which could be used in future lead optimization and biopharmaceutic studies.