In order to drive gas discharge lamps, DC-AC converters with a LCC resonant tank, whose output voltage is adjusted by a
variable frequency control are frequently used. However, when they are activated by varying the operating frequency, converters
are frequently damaged by unstable operation, due to the rising and falling of the operating frequency near the resonant frequency.
To solve this problem, a simple protection circuit for the power supply of a gas discharge lamp is proposed in this paper. This
circuit senses the primary current of the main transformer. Using this protection circuit, the operating frequency of the lamp
driving inverter system is kept close to and on the right side of the resonant frequency and the inverter is always operated in
the ZVS condition. The resulting stable variable frequency operation allows various gas discharge lamps to be tested without the
risk of damaging the main switches, because the protection circuit can protect the power MOSFETs of bridge converters from
abnormal conditions. The validity and effectiveness of the proposed protection circuit are verified through the experimental results.