권호기사보기
기사명 | 저자명 | 페이지 | 원문 | 기사목차 |
---|
대표형(전거형, Authority) | 생물정보 | 이형(異形, Variant) | 소속 | 직위 | 직업 | 활동분야 | 주기 | 서지 | |
---|---|---|---|---|---|---|---|---|---|
연구/단체명을 입력해주세요. |
|
|
|
|
|
* 주제를 선택하시면 검색 상세로 이동합니다.
This study analyzes the indoor air quality inspections of newly constructed apartments by the Busan Institute of Health and Environment for the last three years (2021-2023). Of the 41 inspections, 33 exceeded the recommended standard, and the average excess rate was 80.5%. When classified by measuring households, 148 out of 332 exceeded the standards, whereas, the average excess rate by household was 44.6%. Benzene was exceeded in two out of the 332 households; therefore, the excess rate was only 0.6%. However, the relative standard deviation was the largest, showing as the highest item in the scattergram. The average concentration of toluene was 1,006.0 μg/m3, which was 100.6% of the recommended standard and was exceeded by 138 households; hence,ᅠ the excess rate was 41.6%. All six items(Formaldehyde, Benzene, Toluene, Ethylbenzene, Xylene, Styrene) reached the highest concentration in spring or summer when the indoor temperature increased. The average concentration of toluene in July was 1,922 μg/m3, close to 1.9 times the recommended standard; toluene is considered ᅠ an item of particular concern in summer. In the correlation analysis with indoor temperature, the formaldehyde coefficient of determination was 0.4855, regarded as somewhat significant; it was difficult to confirm the correlation with temperature for the other five items, including benzene. In correlation with relative humidity, formaldehyde showed the same tendency as indoor temperature, with a coefficient of determination of 0.4404, which is believed to be due to its small molecular weight and high solubility. Due to the chimney effect, high concentrations of volatile organic compounds could be confirmed at low atmospheric pressure in the upper floors, and this trend was most evident for formaldehyde. For most items(Formaldehyde, Benzene, Toluene, Ethylbenzene, Styrene), a negative correlation was confirmed in which the emission amount decreased as the number of households increased. For large apartment houses, it is believed that it is due to sufficient bake-out and flush- out according to the adequate construction period and the use of eco-friendly and high-end building materials. Small apartments are classified together with many small houses. The emission concentration of small houses is relatively high because the proportion of the surface area where pollutants are released is high.
*표시는 필수 입력사항입니다.
*전화번호 | ※ '-' 없이 휴대폰번호를 입력하세요 |
---|
기사명 | 저자명 | 페이지 | 원문 | 기사목차 |
---|
번호 | 발행일자 | 권호명 | 제본정보 | 자료실 | 원문 | 신청 페이지 |
---|
도서위치안내: 정기간행물실(524호) / 서가번호: 국내15
2021년 이전 정기간행물은 온라인 신청(원문 구축 자료는 원문 이용)
우편복사 목록담기를 완료하였습니다.
*표시는 필수 입력사항입니다.
저장 되었습니다.