In keeping with the development of machine tools with higher speed, more axes, and a greater degree of sophistication,
thermal deformation is becoming an important factor in the precision of machine tools. It has been found that thermal error
accounts for about 70% of the total error in machine tools. As such, oil coolers which absorb heat from heat generating
parts with cold oil are being used to reduce the error caused by thermal deformation. The gas bypass type oil coolers used
in ultra-precision (temperature accuracy within ±0.1℃) machine tools are simple in structure and precise in terms of their
temperature control performance; however, they have a limitation as regards temperature control due to the instability of
their performance under light load conditions. In this study, an oil cooler system equipped with dual electronic valves was
developed to solve the problems of the single electronic valve system and achieve more precise temperature control. To
verify the performance of the developed system, its performance under the operating conditions of rated load, DIN 8602
standard, and ISO/DIS 230-3 operational mode was compared and analyzed. The proposed oil cooler system is applicable
to semiconductor equipment, ultra-precision injection molds, and ultra-precision machine tools, and improves the quality of
the products.| 번호 | 참고문헌 | 국회도서관 소장유무 |
|---|---|---|
| 1 | International Status of Thermal Error Research (1990) ![]() |
미소장 |
| 2 | Weck, M., McKeown, P. A., Bonse, R. and Herbst, U., “Reduction and compensation of thermal error in machine tools,” Annals of the CIRP, Vol. 42, No. 2, pp. 589-598, 1995. | 미소장 |
| 3 | Capacity Control for Refrigeration and Air-Conditioning Systems: A Comparative Study ![]() |
미소장 |
| 4 | A comparison of hot-gas by-pass and suction modulation method for partial load control in refrigerated shipping containers ![]() |
미소장 |
| 5 | Frost retardation of an air-source heat pump by the hot gas bypass method ![]() |
미소장 |
| 6 | Performance of a showcase refrigeration system with multi-evaporator during on–off cycling and hot-gas bypass defrost ![]() |
미소장 |
| 7 | Performances of Hot Gas Bypass Type Oil Cooler System | 소장 |
| 8 | Statham, A., Martin, A. and Blackshaw, D. M. S., “Assessing the thermal distortion caused by spindle rotation of a machining center using draft standard ISO/DIS 230-3,” Laser Metrology and Machining Performance III, Vol. 16, pp. 101-111, 1997. | 미소장 |
| 9 | Cycle performance study on R32/R125/R161 as an alternative refrigerant to R407C ![]() |
미소장 |
| 10 | Reliability Evaluation of an Oil Cooler for a High-Precision Machining Center | 소장 |
| 11 | Evaluation of machinability according to the changes in machine tools and cooling lubrication environments and optimization of cutting conditions using Taguchi method | 소장 |