Background: To validate Omron HEM 907 XL blood pressure monitor (test device) against auscultatory mercury sphygmomanometer in children aged 7–18 years old in accordance with International Protocol of European Society of Hypertension revised in 2010 (ESH-IP2) and British Hypertension Society (BHS) protocol. Methods: Seventy-five children and adolescents were recruited for the study. A validation procedure was performed following the protocol which was prepared on the basis of ESH-IP2 and BHS protocol for children and adolescents. Each underwent 7 sequential blood pressure (BP)measurements alternatively with a mercury sphygmomanometer and the test device. The results were analyzed according to the validation criteria of ESH-IP2. Results: The mean BP (± standard deviation [SD]) difference of absolute value between the test device and mercury sphygmomanometer readings in all the 75 subjects was 3.26 ± 3.08 mm Hg for systolic BP and 4.11 ± 3.50mm Hg for diastolic BP. These results fulfilled AAMI criterion of mean ± SD below 5 ± 8 mm Hg for both systolic and diastolic BP. The proportion of test device-observer mercury sphygmomanometer BP differences within 5, 10 and 15 mm Hg were 81%,96%, 99% for SBP and 72%, 93%, 99% for diastolic blood pressure (DBP), respectively, in the part 1 analysis, so both systolic blood pressure (SBP) and DBP passed the part 1 criteria. As for the part 2 analysis, SBP passed the criteria, bur DBP failed. Conclusions: Omron HEM 907 XL BP monitor failed an adapted ESH-IP2, though SBP passed. When comparing the BP readings by oscillometers with mercury sphygmomanometer, the differences between them, particularly in diastolic BP, should be taken into account, because DBP can be underestimated.

권호기사

권호기사 목록 테이블로 기사명, 저자명, 페이지, 원문, 기사목차 순으로 되어있습니다.
기사명 저자명 페이지 원문 목차
Antihypertensive therapy considering the prevention of vascular aging Toshihiko Ishimitsu pp.85-94

Aronox 추출물의 대사장애와 고혈압의 예방과 치료에 관한 효능연구 박영미, 박정배 pp.95-102

본태성 고혈압 환자에서 S-(-)-Amlodipine Nicotinate와 Ramipril의 유효성 및 안정성의 비교 평가 김민석, 정명호, 이민구, 심두선, 박근호, 윤남식, 윤현주, 김계훈, 홍영준, 김주한, 안영근, 조정관, 박종춘, 강정채 pp.103-113

오므론 HEM 907 XL 자동 진동식 혈압계와 수동 수은혈압계의 오차에 미치는 연령의 영향 이종국, 박지원, 문진수, 김남수, 김기혁 pp.114-124

고혈압 환자에서 대사증후군 평가의 유용성 이소령, 김대중, 성기철, 조은주, 현민수, 박정배, 김영권, 이인규, 김철호, 이해영 pp.125-132

참고문헌 (19건) : 자료제공( 네이버학술정보 )

참고문헌 목록에 대한 테이블로 번호, 참고문헌, 국회도서관 소장유무로 구성되어 있습니다.
번호 참고문헌 국회도서관 소장유무
1 Determinants of cardiac involvement in children and adolescents with essential hypertension. 네이버 미소장
2 Mechanisms of Disease: in utero programming in the pathogenesis of hypertension 네이버 미소장
3 Overweight, ethnicity, and the prevalence of hypertension in school-aged children. 네이버 미소장
4 Estimating the Burden of Diseases due to Hypertension in Korea 네이버 미소장
5 The fourth report on the diagnosis, evaluation, and treatment of high blood pressure in children and adolescents. 네이버 미소장
6 Normal blood pressure values and percentile curves below 3 years of age in Korea 네이버 미소장
7 Korea Centers for Disease Control and Prevention. The Korean Pediatric Society, Committee on Growth Chart of Korean Children and Adolescents. 2007 Korean national growth charts, Seoul: Korea Centers for Disease Control and Prevention, The Korean Pediatric Society, 2007. 미소장
8 Normative blood pressure references for Korean children and adolescents 소장
9 Pickering TG. What will replace the mercury sphygmomanometer? Blood Press Monit. 2003;8:23-5. 미소장
10 MD. 네이버 미소장
11 The British Hpertension Society protocol for the evaluation of blood pressure measuring devices. 네이버 미소장
12 European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults 네이버 미소장
13 Association for the Advancement of Medical Instrumentation (AAMI). The national standard of electronic or automated sphygmomanometers. Arlington, VA: AAMI; 1987. 미소장
14 Validation of three oscillometric blood pressure devices against auscultatory mercury sphygmomanometer in children 네이버 미소장
15 Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults 네이버 미소장
16 O'Brien E. Formation of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. Blood Press Monit. 1998;3:133-4. 미소장
17 STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT 네이버 미소장
18 The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems. 네이버 미소장
19 Validation of A&D UA-778 blood pressure monitor in children 네이버 미소장