본문 바로가기 주메뉴 바로가기
국회도서관 홈으로 정보검색 소장정보 검색

결과 내 검색

동의어 포함

초록보기

Since operating conditions are significantly different for heating and cooling mode operations in a CO₂ heat pump system, it is difficult to optimize the performance of the CO₂ cycle. In addition, the performance of a CO₂ heat pump is very sensitive to outdoor temperature and gascooler pressure. In this study, the cooling and heating performances of a variable speed CO₂ heat pump with a twin-rotary compressor were measured and analyzed with the variations of EEV opening and compressor frequency. As a result, the cooling and heating COPs were 2.3 and 3.0, respectively, when the EEV opening was 22%. When the optimal EEV openings for heating and cooling were 28% and 16%, the cooling and heating COPs increased by 3.3% and 3.9%, respectively, over the COPs at the EEV opening of 22%. Beside, the heating performance was more sensitive to EEV opening than the cooling performance. As the compressor speed decreased by 5 Hz, the cooling COP increased by 2%, while the heating COP decreased by 8%.

권호기사

권호기사 목록 테이블로 기사명, 저자명, 페이지, 원문, 기사목차 순으로 되어있습니다.
기사명 저자명 페이지 원문 목차
전자모듈의 배열에 따른 열전달특성의 실험적 연구 이대희 ; 이대근 ; 차윤석 ; 이준식 pp.407-412

유동 섭동에 의한 난류예혼합화염의 열발생 모델에 관한 연구 조주형 ; 백승욱 pp.413-420

3차원 입자와법을 이용한 높은 스트롤수로 진동하는 구에 대한 유동장의 수치해석 이상환 ; 박윤섭 ; 조영택 ; 안철오 ; 서인수 pp.421-428

2차원 압축공기-물의 압축성 이상 유동 수치 해석 박찬욱 ; 이승수 pp.429-445

자동차용 고분자 연료전지 수소 재순환 시스템의 이상 유동해석 곽현주 ; 정진택 ; 김재춘 ; 김용찬 ; 오형석 pp.446-453

운전조건 변화에 따른 이산화탄소 열펌프의 냉난방 성능특성 비교 조홍현 ; 백창현 ; 이응찬 ; 강 훈 ; 김용찬 pp.454-462

표면조도가 있는 난류경계층 내 난류구조 이재화 ; 이승현 ; 김경연 ; 성형진 pp.463-470

DES 기법을 이용한 270˚곡덕트에서 발달하는 난류 유동의 수치해석 서정식 ; 신종근 ; 최영돈 ; 이주철 pp.471-478

SMX 형 정적 믹서의 압력손실 특성 양희천 ; 박정일 pp.479-486

참고문헌 (11건) : 자료제공( 네이버학술정보 )

참고문헌 목록에 대한 테이블로 번호, 참고문헌, 국회도서관 소장유무로 구성되어 있습니다.
번호 참고문헌 국회도서관 소장유무
1 CO 2-heat pump water heater: characteristics, system design and experimental results 네이버 미소장
2 Hrnjak, P, (2000) Transcritical Co2 Heat Pump for Residential Application, 4Th Iir-Gustav Loren- tzen Natural Working Fluids Conference At Purdue 미소장
3 Sarkar J, (2004) Optimization of a Transcritical Co2 Cycle for Simultaneous Cooling and Heating Applications, Int. Journal of Refrigeration 미소장
4 Sarkar J, (2006) Simulation of a Transcritical Co2 Heat Pump Cycle for Simultaneous Cooling and Heating Applications, Int. Journal of Refrigeration 미소장
5 Chen, Y, (2005) The Optimum High Pressure for Co2 Transcritical Refrigeration Systems with Internal Heat Exchangers, Int. Journal of Refrigeration 미소장
6 Stene J, (2005) Residential Co2 Heat Pump System for Combined Space Heating and Hot Water Heating, Int. Journal of Refrigeration 미소장
7 Experimental results of transcritical CO 2 heat pump for residential application 네이버 미소장
8 Ashrae, (2005) Engineering Analysis Of Experi mental Data, in: Ashrae Guideline 2, Ashrae 미소장
9 Cooling performance of a variable speed CO 2 cycle with an electronic expansion valve and internal heat exchanger 네이버 미소장
10 Ashrae, (1983) Methods of Testing For Seasonal Efficiency of Unitary Air-Conditioner and Heat Pumps, in:Ashrae Standard 116, Ashrae 미소장
11 Cho, H, (2007) Experimental Study on the Heating Performance of a Variable Speed Co2 Heat Pump with a Variation of Operating Conditions, Ksme Korean Journal(B) 미소장