권호기사보기
| 기사명 | 저자명 | 페이지 | 원문 | 기사목차 |
|---|
결과 내 검색
동의어 포함
We report a method for optical monitoring of tumors in an animal model using optical coherence
tomography (OCT). In a spectral domain OCT system, a superluminescent diode light source with a full
width of 66 nm at half maximum and peak wavelength of 950 nm was used to take images having an
axial resolution of 6.8 μ m. Cancer cells of PC-3 were cultured and inoculated into the hypodermis of
auricle tissues in BALB/c nude mice. We observed tumor formation and growth at the injection region
of cancer cells in vivo and obtained the images of tumor mass center and sparse circumferences. On the
5th day from an inoculation of cancer cells, histological images of the tumor region using cross-sectional
slicing and dye staining of specimens were taken in order to confirm the correlation with the high resolution
OCT images. The OCT image of tumor mass compared with normal tissues was analyzed using its A-scan
data so as to obtain a tissue attenuation rate which increases according to tumor growth.| 번호 | 참고문헌 | 국회도서관 소장유무 |
|---|---|---|
| 1 | Ultrahigh-resolution ophthalmic optical coherence tomography | 미소장 |
| 2 | Cumulative Imaging Radiation Exposure Following Breast-Conservation Therapy | 미소장 |
| 3 | Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media | 미소장 |
| 4 | Estimation of the secondary cancer risk induced by diagnostic imaging radiation during proton therapy | 미소장 |
| 5 | THE MELANOSOME: THRESHOLD TEMPERATURE FOR EXPLOSIVE VAPORIZATION AND INTERNAL ABSORPTION COEFFICIENT DURING PULSED LASER IRRADIATION | 미소장 |
| 6 | Angiogenesis in cancer, vascular, rheumatoid and other disease | 미소장 |
| 7 | Fourier Domain Optical Coherence Tomography for Retinal Imaging with 800-nm Swept Source: Real-time Resampling in k-domain | 미소장 |
| 8 | In Vivo Optical Coherence Tomography | 미소장 |
| 9 | Empirical model functions to calculate hematocrit-dependent optical properties of human blood | 미소장 |
| 10 | In vivo volumetric imaging of chicken retina with ultrahigh-resolution spectral domain optical coherence tomography | 미소장 |
| 11 | In Vivo Three-Dimensional High-Resolution Imaging of Rodent Retina with Spectral-Domain Optical Coherence Tomography | 미소장 |
| 12 | Wide tuning range wavelength-swept laser with a single SOA at 1020 nm for ultrahigh resolution Fourier-domain optical coherence tomography | 미소장 |
| 13 | Retinal tumor imaging and volume quantification in mouse model using spectral-domain optical coherence tomography | 미소장 |
| 14 | Parametric imaging of cancer with optical coherence tomography | 미소장 |
| 15 | Noninvasive imaging of in vivo blood flow velocity using optical Doppler tomography | 미소장 |
| 16 | Quantification of the wound healing using polarization-sensitive optical coherence tomography | 미소장 |
| 17 | Optical Doppler tomography | 미소장 |
| 18 | Dynamic Visualization of RGD‐Quantum Dot Binding to Tumor Neovasculature and Extravasation in Multiple Living Mouse Models Using Intravital Microscopy | 미소장 |
| 19 | Complex Conjugate Resolved Retinal Imaging by One-micrometer Spectral Domain Optical Coherence Tomography Using an Electro-optical Phase Modulator | 미소장 |
| 20 | A review of the optical properties of biological tissues | 미소장 |
| 21 | Reliability of phototoxic tests of fluoroquinolones in vitro. | 미소장 |
| 22 | Optical Coherence Tomography | 미소장 |
| 23 | The Biology of Cancer | 미소장 |
| 24 | Optical Coherence Tomography | 미소장 |
*표시는 필수 입력사항입니다.
| 전화번호 |
|---|
| 기사명 | 저자명 | 페이지 | 원문 | 기사목차 |
|---|
| 번호 | 발행일자 | 권호명 | 제본정보 | 자료실 | 원문 | 신청 페이지 |
|---|
도서위치안내: 정기간행물실(524호) / 서가번호: 국내17
2021년 이전 정기간행물은 온라인 신청(원문 구축 자료는 원문 이용)
우편복사 목록담기를 완료하였습니다.
*표시는 필수 입력사항입니다.
저장 되었습니다.