In this study, the effects of lock operations on the infiltration rates for the two window types sliding and lift sliding (LS) are investigated through experiment and simulation. The airtightness levels of the two window types-with locks both on and off-were measured according to the KS F 2292 Test method of airtightness that is used for windows and doors. The air-flow rates of both window types with the locks on for a pressure differential of 10 Pa are 1.98 ㎥/(㎡h) and 1.68 ㎥/(㎡h), respectively; with the locks off, the air-flow rates of the sliding and LS windows are 2.64 ㎥/(㎡h) and 5.83 ㎥/(㎡h), respectively, whereby the air-flow rates are 33% higher for sliding and 247% higher for LS. The air change per hour (ACH) was calculated using the ventilation-simulation software CONTAM. For the sliding window, the ACH changed from 0.45 to 0.57 when the lock was operated from on to off, representing an increase of 27%. For the LS window, the ACH changed from 0.29 to 0.81, showing an increase of 179%.

권호기사

권호기사 목록 테이블로 기사명, 저자명, 페이지, 원문, 기사목차 순으로 되어있습니다.
기사명 저자명 페이지 원문 목차
잠금장치 작동에 따른 미서기 및 LS 창호 시스템의 기밀성 박종준, 윤유라, 김영일, 정광섭 pp.449-454
에어커튼형 레인지후드의 슬롯 토출 각도 변화와 배기 효율 성순경 pp.468-474
단열시트(뽁뽁이)의 종류 및 부착위치에 따른 창호의 단열성능 평가 황제, 정아희, 전병헌, 안영철 pp.463-467
종이와 플라스틱 필름의 이종 재질로 구성된 직교류형 간접증발소자의 성능에 대한 실험적 연구 권미혜, 고민건, 김내현 pp.475-483
건축물 계단에서의 연돌효과 저감방안에 대한 현장실험 연구 김정엽, 김지석, 이수각 pp.484-490
국내 기상조건하 주거용 건물 가스 보일러의 부분부하 특성과 에너지 사용량 분석 유병호, 서병모, 문진우, 이광호 pp.455-462
공조 시스템 내의 분배기 출구관의 삽입깊이에 따른 유량분포연구 이희원, 박일석 pp.491-496

참고문헌 (7건) : 자료제공( 네이버학술정보 )

참고문헌 목록에 대한 테이블로 번호, 참고문헌, 국회도서관 소장유무로 구성되어 있습니다.
번호 참고문헌 국회도서관 소장유무
1 Correlation Analysis Between Fenestration Energy Consumption Efficiency Rating System and Building Energy Consumption 소장
2 Jang, C. Y., Lee, N. E., 2010. A Measurement and Evaluation of Air Tightness of Temperable Low-e Windows Soft glazing, one of manufacturing process of Low-e glazing. Proceedings of the SAREK, 6, 368-371. 미소장
3 Jang, E. S., Ryu, S. W., 2013. An Analytical Study on the Auto Locking System of Aluminium Windows. Proceedings of the IJPEM, 27(6), 105-107. 미소장
4 Korean Standard Association, KS F 2292, 2013. The test method of airtightness for windows and doors. 미소장
5 NIST, 2011. ContamW 3.0.1 Manual, National Institute of Standards and Technology Engineering Laboratory. 미소장
6 Kim, S. S., Park, H. S., 2005. The Study on the Determining of the Infiltration Coefficient by Window Types. Korean Journal of the Architectural Institute of Korea, 21(4), 183-189. 미소장
7 Walton, G. N., Dols, W. S., 2005. CONTAM 2.4User Guide and Program Documentation, National Institute of Standards and Technology. 미소장